man8/TRtask

Table of Contents

Name

TRtask - I/O service for an KSC4010 and KSC4022 transient recorders

Synopsis

TRtask <argument list>

Description

I/O service for Kinetic Systems 4010 and 4022 transient recorders.

This program is part of the NEC AMS dosimetry system.

Arguments

Argument processing is done using Unix long argument syntax.

All of the parameters listed here are printed on stderr when the program starts, whether or not they were supplied on the command line.

--dbman_host <hn>

The host where dbman is running. If this argument is not supplied the default is "localhost" or the DBMAN_HOST environment variable.
--mbs_host <hn>

The host where MBSseqTask is running. If this argument is not supplied the default is "localhost" or the MBS_HOST environment variable.
--dose_host <hn>

The host where DOSEserv is running. If this argument is not supplied the default is "localhost or the DOSE_HOST environment variable.
--drv <drv>

The driver key. If this argument is not supplied the the default is "CAMAC"
--cmin <n>

The minimum crate number. If this argument is not supplied the default is 0.
--cmax <n>

The maximum crate number. If this argument is not supplied the default is 99.
--show_tbl

Turns on printing of internal tables when possible.
--help

Prints a help message out.

4010 Device Types

4010le0v
4010 - tr le ch 0 vr
4010le1v
4010 - tr le ch 1 vr
4010le2v
4010 - tr le ch 2 vr
4010le3v
4010 - tr le ch 3 vr
4010le4v
4010 - tr le ch 4 vr
4010le5v
4010 - tr le ch 5 vr

4010he0v
4010 - tr he ch 0 vr
4010he1v
4010 - tr he ch 1 vr
4010he2v
4010 - tr he ch 2 vr
4010he3v
4010 - tr he ch 3 vr
4010he4v
4010 - tr he ch 4 vr
4010he5v
4010 - tr he ch 5 vr

4022 Device Types

4022le0v
4022 - tr le ch 0 vr
4022le1v
4022 - tr le ch 1 vr
4022le2v
4022 - tr le ch 2 vr
4022le3v
4022 - tr le ch 3 vr
4022le4v
4022 - tr le ch 4 vr
4022le5v
4022 - tr le ch 5 vr

4022he0v
4022 - tr he ch 0 vr
4022he1v
4022 - tr he ch 1 vr
4022he2v
4022 - tr he ch 2 vr
4022he3v
4022 - tr he ch 3 vr
4022he4v
4022 - tr he ch 4 vr
4022he5v
4022 - tr he ch 5 vr

Common Device Types

TRANle0c
- tr le ch 0 cr
TRANle1c
- tr le ch 1 cr
TRANle2c
- tr le ch 2 cr
TRANle3c
- tr le ch 3 cr
TRANle4c
- tr le ch 4 cr
TRANle5c
- tr le ch 5 cr

TRANhe0c
- tr he ch 0 cr
TRANhe1c
- tr he ch 1 cr
TRANhe2c
- tr he ch 2 cr
TRANhe3c
- tr he ch 3 cr
TRANhe4c
- tr he ch 4 cr
TRANhe5c
- tr he ch 5 cr

TRANle0a
- tr le ch 0 I avg
TRANle1a
- tr le ch 1 I avg
TRANle2a
- tr le ch 2 I avg
TRANle3a
- tr le ch 3 I avg
TRANle4a
- tr le ch 4 I avg
TRANle5a
- tr le ch 5 I avg

TRANhe0a
- tr he ch 0 I avg
TRANhe1a
- tr he ch 1 I avg
TRANhe2a
- tr he ch 2 I avg
TRANhe3a
- tr he ch 3 I avg
TRANhe4a
- tr he ch 4 I avg
TRANhe5a
- tr he ch 5 I avg

3660 Counter/Timer Device Types

3660le0c
3660 - le ch 0 cnt
3660le1c
3660 - le ch 1 cnt
3660le2c
3660 - le ch 2 cnt
3660le3c
3660 - le ch 3 cnt
3660le4c
3660 - le ch 4 cnt
3660le5c
3660 - le ch 5 cnt

3660he0c
3660 - he ch 0 cnt
3660he1c
3660 - he ch 1 cnt
3660he2c
3660 - he ch 2 cnt
3660he3c
3660 - he ch 3 cnt
3660he4c
3660 - he ch 4 cnt
3660he5c
3660 - he ch 5 cnt

3660le0d
3660 - le ch 0 dly
3660le1d
3660 - le ch 1 dly
3660le2d
3660 - le ch 2 dly
3660le3d
3660 - le ch 3 dly
3660le4d
3660 - le ch 4 dly
3660le5d
3660 - le ch 5 dly

3660he0d
3660 - he ch 0 dly
3660he1d
3660 - he ch 1 dly
3660he2d
3660 - he ch 2 dly
3660he3d
3660 - he ch 3 dly
3660he4d
3660 - he ch 4 dly
3660he5d
3660 - he ch 5 dly

I/O polling rates

Polling is normally performed at 1Hz. Fast polling at 10Hz is supported.

Examples

#
# this example services crates 1 thru 4
# dbman is running on the same host
# MBSseqTask is running on the same host
# DOSEserv is running on the same host
#
TRtask --cmin 1 --cmax 4

Misc

This program responds to diagnostic logging using diag2.

Manual page revision

$Id: TRtask.8,v 1.5 2007/07/17 20:17:47 mcnamer Exp $